back BACK

Multi-Parameter Troll 9000

P/N Troll9000

The NEW Standard for Water Quality Monitoring!

FirstCheck 6000 PPB PID/Multigas DetectorIntroducing the new Multi-Parameter (MP) TROLL 9000 for water quality monitoring. Designed with the highest quality 316L stainless steel, the TROLL 9000 is very rugged yet lightweight. Capable of monitoring up to 9 sensors simultaneously, the MP TROLL 9000 is the ultimate tool for water quality profiling applications and unattended, long-term deployments. The MP TROLL 9000 features many new technological innovations such as "Smart Sensors", "Digital D.O.", "Optional Pre-Calibrated Sensors", "Single Quick-Calibration Solutions", and more. Get a fresh perspective on water quality with the new MP TROLL 9000.

 

Daily Weekly Monthly  
$ 95 $ 330 $ 800  

Features:

  • Smart Sensors that are 'Plug and Play' remember calibration
  • Digital D.O.™ -- no stirring required.
  • Single "Quick-Cal" solution -- calibrate most sensors at the same time!
  • The most sensors in a 45mm (1.75") diameter-- up to 9 sensors
  • Pre-Calibrated and ready to use -- Ready to use right out of the box!
  • Flexible sensor ports -- add sensors of your choice to any port
  • Small, lightweight design using high quality 316L stainless steel
  • Internal datalogger with up to 4MB (1,760,000 data points!)
  • User-replaceable, powerful D batteries provide maximum power -- up to 6 months.
  • Vented Quick-Connect cable (FEP or Polyurethane) -- Fully detachable!
  • Internal barometric sensor -- record real-time barometric changes
  • Networking and telemetry capable
  • Multiple product versions -- select features to match your budget. Always upgradeable!

MP TROLL 9000 Versions

Basic

Profiler

Profiler XP

Professional

Professional XP

LTS

Available WQ Sensor Ports 4 4 4 4 4 1
Sensors            
Dissolved Oxygen, (% & mg/L)

Digital D.O. (No stirring required)

 

Conductivity, SC, TDS, Resistivity

Temperature

pH

ORP

pH/ORP

 

Salinity

 

Level, Depth, Pressure

 

Barometric Pressure

 

Nitrate    

 

 

Chloride    

 

 

Ammonium, Ammonia    

 

 

Turbidity    

 

 

Replaceable Sensors Requires Upgrade

Data Logging      

Memory (data points)      

4MB (1.76 mil dp)

4MB (1.76 mil dp)

4MB (1.76 mil dp)

Number of tests stored      

16

16

16

Linear tests      

Linear average tests      

Logarithmic tests      

Event Tests      

Min. sampling rate (sec)

0.5 - 2

0.5 - 2

0.5 - 2

0.5 - 2

0.5 - 2

0.5 - 2

Telemetry capability      

Networking capability        

Automation      

Upgradeable

 

 

Quick calibration
High-accuracy calibration